About Us
Since 2014, Developing Excellence With Quality At It’s Best!
Founder & Brand Story
Developed by Dr. Chien-Hai Lee, Director of Chuan Sheng Dental Clianic in Hualien, Taiwan. Since graduating from the Department of Implantology at Goethe University Frankfurt, Germany, in 2011, Dr. Lee has dedicated over a decade to intraoral welding technology and has been invited to speak at international conferences in Italy multiple times. In 2018, he officially introduced the “OneDayWall” full-mouth rehabilitation technique, committed to providing patients with a premium treatment experience where implants and metal-reinforced final prostheses are delivered on the very same day.
Following Dr. Degidi’s profession of electric resistence application on intraloral welding , we started to explore.Therefater,under the same philosiphy, transferring to model mounted in the articulator for more stronger structure of welding framework with PMMA fabrication clinically in less one day.Dr. Chien-Hai Li and all his fellow and team had built up a smooth,stable,verified and super fast protocol of same day dental implant restoration,named “One Day Wall”. It had created so many successfull cases to help patients restore their happiness and smiles less in one day.
Core Technology
Instant Resistance Spot Welding onto Fusion of Pure Titanium: Ultra-Strong & Highly Precise
Using Italian-origin Intraoral Welding technology, a resistance spot welder permanently connects pure titanium wire to the copings in milliseconds. This procedure generates no thermal injury to surrounding soft tissues while rapidly establishing a strong, rigid full-arch titanium framework.
Biomechanical Advantage: 525% Strain Reduction on Abutments
Finite Element Analysis: Protecting Implants and Bone
Clinical data and Finite Element Analysis show that adding a pure titanium framework significantly distributes occlusal forces, reducing strain on abutments by up to 525%! The rigid splinting mechanism locks implants together to prevent micro-movements, greatly enhancing the success rate and effeciency of osseointegration.
12-Year Long-Term Clinical Evidence
Tested for 12 Years: Proven Reliability Under Extreme Conditions
Continuous clinical follow-ups extending to 12 years—including cases involving high bite forces and heavy betel nut chewing—demonstrate that the prosthesis remains fully intact! CBCT imaging even shows bone preservation and growth under the distal cantilever. Exceptional durability offers patients the ultimate peace of mind..
Conometric Friction-Fit System
No Screws, No Cement: Conometric Friction-Fit Retention
Free from the vulnerability of traditional screw-retained restorations that frequently fracture around access holes, One Day Wall utilizes high-precision physical friction-fit retention. Without unsightly screw access holes, the restoration achieves a superior natural aesthetic while minimizing the risk of acrylic chipping and food trap accumulation.
A Breakthrough in Full-Mouth Reconstruction: Same-Day Final Prosthesis.
Beyond Tradition: Say Goodbye to Fracturing Provisional
All-on-X procedures often rely on all-acrylic provisional, which carry a mechanical complication rate exceeding 80%. OneDayWall makes it possible to deliver a final prosthesis with an integrated pure titanium metal framework on the day of surgery. This provides superior rigidity and stability, completely eliminating the frustration of provisional fractures during the healing period
Our Solutions
Full mouth Rehab. & Crown Bridges!

Ergonomic Harmony: Self-Adapting Occlusal Alignment。Adaptive Prosthesis: Automatic Muscle & Joint Balance。
While in surgery, patient muscle fatigue can cause temporary bite deviations. The One Day Wall prosthesis possesses micro-wear adaptability that gradually aligns with the patient’s masticatory muscles and temporomandibular joint over time, achieving long-term balanced occlusion.

Patented Custom Tray & Lab Innovation。Streamlined Workflow: Seamless Doctor-Technician Synergy。
Through custom individual tray and Shell technology, impression taking, vertical dimension (V.D.) recording, and coping capture are combined into a single clinical step. Standardizing complex laboratory procedures dramatically reduces the chairside time required on surgery day.

Bone Preservation: Minimally Invasive Approach。Preserve More, Bone-Friendly: Less Reduction, Better Maintenance 。
Traditional All-on-X often require extensive bone reduction to accommodate thick restorative materials. One Day Wall requires only 8 mm of restorative space to fabricate a high-strength prosthesis, maximizing the preservation of natural alveolar bone for easier hygiene and maintenance.

Efficient Hygiene: 2-Minute Retrieval & Re-insertion。Effortless Maintenance saves clinical time。
Screw-retained full-arch prostheses take over 30 minutes to unscrew and clean (with risk of screw wear), OneDayWall’s friction-fit system allows dentists to gently dislodge the prosthesis for deep cleaning and re-seat it in just 2 to 3 minutes, making routine maintenance fast and hassle-free.

Clinical & Labo Support Network。Supported by Authorized Dental Clinics & Master Technicians.。
ConeWeld partners with the Topo team, uniting skilled removable technicians, abundant implant component stock, and multi-angle abutment options. Our service network spans dozens of renowned dental clinics and hospitals across Taiwan, delivering timely, professional support wherever you are.

Broad Compatibility: Supporting 20+ Implant Systems。Highly Versatile, Compatible Globally 。
OneDayWall features outstanding cross-platform compatibility, supporting over 20 major international implant systems—including Superline, Osstem, Ankylos, Astra, Straumann, and Bredent. No matter which implant system is placed, it seamlessly pairs with Conometric abutments.